| Code / Price |
Name / Description |
BLS4135
$3.95
Quantity in Basket:
none
|
Boot Reset Button Clear
Boot Reset Button Clear
| Boot Thread | 3/8"-27 |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
Replaces standard mounting nut for mounting on Thermal Push Button Circuit Breakers onlyUV resistant material resists discoloration and cracking
|
BLS4137
$3.78
Sorry, This Item is No Longer Available.
Quantity in Basket:
none
|
Boot Reset Button Black
Boot Reset Button Black
| Boot Thread | 3/8"-27 |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
Replaces standard mounting nut for mounting on Thermal Push Button Circuit Breakers onlyUV resistant material resists discoloration and cracking
|
BLS7002
$44.37
Quantity in Basket:
none
|
Circuit Breaker, Panel 100 A
Circuit Breaker,100 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Interrupt Rating | 3,000 Amperes |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Circuit Breaker Class | Type III - Switchable/Manual Reset - Trip Free |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Trip Time Delay | See |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.25 (0.11) |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7052
$6.95
Quantity in Basket:
none
|
Circuit Breaker Push Button 5A
Circuit Breaker Push Button 5A
| Boot Thread | 3/8"-27 |
|---|
| Maximum Voltage Rating | 28 Volts DC |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
| Operating Temperature Range | -10 degrees C to +60 degrees C |
|---|
| Trip Time Delay | See |
|---|
| Weight Lb (Kg) | Circuit Breaker 0.06Lb (0.03Kg) |
|---|
| Weight Lb (Kg) | Waterproof boots (package of 5) 0.04 Lb (0.02 Kg) |
|---|
| Circuit Breaker Type | Thermal trip, manual push-button reset only |
|---|
| Interrupt Rating | 2,500 Amperes DC |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
Ideal for 24-hour circuit protectionIncorporated into Blue Sea Systems' Waterproof Circuit Breaker panels and main Battery Main Distribution PanelsPush to reset operationôTrip Free™ design cannot be held ôON™ during fault current conditionIgnition protected - Safe for installation aboard gasoline powered boatsOptional Push Button Waterproof Boot protects circuit breaker in wet environments, replaces dress nut mounting on circuit breakers and resists dicoloration and cracking
Trip Delay Curve
|
BLS7054
$6.95
Quantity in Basket:
none
|
Circuit Breaker Push Button 10A
Circuit Breaker Push Button 10A
| Boot Thread | 3/8"-27 |
|---|
| Maximum Voltage Rating | 28 Volts DC |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
| Operating Temperature Range | -10 degrees C to +60 degrees C |
|---|
| Trip Time Delay | See |
|---|
| Weight Lb (Kg) | Circuit Breaker 0.06Lb (0.03Kg) |
|---|
| Weight Lb (Kg) | Waterproof boots (package of 5) 0.04 Lb (0.02 Kg) |
|---|
| Circuit Breaker Type | Thermal trip, manual push-button reset only |
|---|
| Interrupt Rating | 2,500 Amperes DC |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
Ideal for 24-hour circuit protectionIncorporated into Blue Sea Systems' Waterproof Circuit Breaker panels and main Battery Main Distribution PanelsPush to reset operationôTrip Free™ design cannot be held ôON™ during fault current conditionIgnition protected - Safe for installation aboard gasoline powered boatsOptional Push Button Waterproof Boot protects circuit breaker in wet environments, replaces dress nut mounting on circuit breakers and resists dicoloration and cracking
Trip Delay Curve
|
BLS7056
$7.41
Quantity in Basket:
none
|
Circuit Breaker Push Button 15A
Circuit Breaker Push Button 15A
| Boot Thread | 3/8"-27 |
|---|
| Maximum Voltage Rating | 28 Volts DC |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
| Operating Temperature Range | -10 degrees C to +60 degrees C |
|---|
| Trip Time Delay | See |
|---|
| Weight Lb (Kg) | Circuit Breaker 0.06Lb (0.03Kg) |
|---|
| Weight Lb (Kg) | Waterproof boots (package of 5) 0.04 Lb (0.02 Kg) |
|---|
| Circuit Breaker Type | Thermal trip, manual push-button reset only |
|---|
| Interrupt Rating | 2,500 Amperes DC |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
Ideal for 24-hour circuit protectionIncorporated into Blue Sea Systems' Waterproof Circuit Breaker panels and main Battery Main Distribution PanelsPush to reset operationôTrip Free™ design cannot be held ôON™ during fault current conditionIgnition protected - Safe for installation aboard gasoline powered boatsOptional Push Button Waterproof Boot protects circuit breaker in wet environments, replaces dress nut mounting on circuit breakers and resists dicoloration and cracking
Trip Delay Curve
|
BLS7057
$7.41
Quantity in Basket:
none
|
Circuit Breaker Push Button 20A
Circuit Breaker Push Button 20A
| Boot Thread | 3/8"-27 |
|---|
| Maximum Voltage Rating | 28 Volts DC |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
| Operating Temperature Range | -10 degrees C to +60 degrees C |
|---|
| Trip Time Delay | See |
|---|
| Weight Lb (Kg) | Circuit Breaker 0.06Lb (0.03Kg) |
|---|
| Weight Lb (Kg) | Waterproof boots (package of 5) 0.04 Lb (0.02 Kg) |
|---|
| Circuit Breaker Type | Thermal trip, manual push-button reset only |
|---|
| Interrupt Rating | 2,500 Amperes DC |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
Ideal for 24-hour circuit protectionIncorporated into Blue Sea Systems' Waterproof Circuit Breaker panels and main Battery Main Distribution PanelsPush to reset operationôTrip Free™ design cannot be held ôON™ during fault current conditionIgnition protected - Safe for installation aboard gasoline powered boatsOptional Push Button Waterproof Boot protects circuit breaker in wet environments, replaces dress nut mounting on circuit breakers and resists dicoloration and cracking
Trip Delay Curve
|
BLS7059
$7.41
Quantity in Basket:
none
|
Circuit Breaker Push Button 30A
Circuit Breaker Push Button 30A
| Boot Thread | 3/8"-27 |
|---|
| Maximum Voltage Rating | 28 Volts DC |
|---|
| Boot Material | UV Resistant Silicone Rubber |
|---|
| Operating Temperature Range | -10 degrees C to +60 degrees C |
|---|
| Trip Time Delay | See |
|---|
| Weight Lb (Kg) | Circuit Breaker 0.06Lb (0.03Kg) |
|---|
| Weight Lb (Kg) | Waterproof boots (package of 5) 0.04 Lb (0.02 Kg) |
|---|
| Circuit Breaker Type | Thermal trip, manual push-button reset only |
|---|
| Interrupt Rating | 2,500 Amperes DC |
|---|
| Boot Thread Material | Nickel-Plated Brass |
|---|
Ideal for 24-hour circuit protectionIncorporated into Blue Sea Systems' Waterproof Circuit Breaker panels and main Battery Main Distribution PanelsPush to reset operationôTrip Free™ design cannot be held ôON™ during fault current conditionIgnition protected - Safe for installation aboard gasoline powered boatsOptional Push Button Waterproof Boot protects circuit breaker in wet environments, replaces dress nut mounting on circuit breakers and resists dicoloration and cracking
Trip Delay Curve
|
BLS7100
$44.37
Quantity in Basket:
none
|
Circuit Breaker, SfcMt 050 A
Circuit Breaker, 050 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Trip Time Delay | see |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Circuit Breaker Class | Type iii - Switchable/Manual Reset - Trip Free |
|---|
| Interrupt Rating | 3,000 Amperes DC |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.30 (0.14) |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7102
$44.37
Quantity in Basket:
none
|
Circuit Breaker, SfcMt 100 A
Circuit Breaker, 100 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Trip Time Delay | see |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Circuit Breaker Class | Type iii - Switchable/Manual Reset - Trip Free |
|---|
| Interrupt Rating | 3,000 Amperes DC |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.30 (0.14) |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7104
$44.37
Quantity in Basket:
none
|
Circuit Breaker, SfcMt 150 A
Circuit Breaker, 150 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Trip Time Delay | see |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Circuit Breaker Class | Type iii - Switchable/Manual Reset - Trip Free |
|---|
| Interrupt Rating | 3,000 Amperes DC |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.30 (0.14) |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7105
$44.37
Quantity in Basket:
none
|
Circuit Breaker, SfcMt 040 A
Circuit Breaker, 040 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Trip Time Delay | see |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Circuit Breaker Class | Type iii - Switchable/Manual Reset - Trip Free |
|---|
| Interrupt Rating | 3,000 Amperes DC |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.30 (0.14) |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7114
$44.37
Quantity in Basket:
none
|
Circuit Breaker, SfcMt 80 A
Circuit Breaker, 80 A
| Operating Temperature Range | -25 degrees C to +82 degrees C |
|---|
| Trip Time Delay | see |
|---|
| Terminal Stud Torque | 70 in-lb |
|---|
| Circuit Breaker Class | Type iii - Switchable/Manual Reset - Trip Free |
|---|
| Interrupt Rating | 3,000 Amperes DC |
|---|
| Case Material | Phenolic |
|---|
| Weight Lb (Kg) | 0.30 (0.14) |
|---|
| Circuit Breaker Type | Thermally responsive bi-metal blade |
|---|
| Maximum Voltage Rating | 42 Volts DC |
|---|
| |
|---|
Ignition protected - Safe for installation aboard gasoline powered boatsMeets SAE J1171 external ignition protection requirementsWeather ResistantCombines switching and circuit breaker function into one unit"Trip Free" - cannot be held closed after trip
Trip Delay Curve
|
BLS7202
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 5A White
Circuit Breaker AA1 5A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7204
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 10A Black
Circuit Breaker AA1 10A Black
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7206
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 10A White
Circuit Breaker AA1 10A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7208
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 15A Black
Circuit Breaker AA1 15A Black
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7210
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 15A White
Circuit Breaker AA1 15A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7212
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 20A Black
Circuit Breaker AA1 20A Black
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7214
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 20A White
Circuit Breaker AA1 20A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7218
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 25A White
Circuit Breaker AA1 25A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7220
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 30A Black
Circuit Breaker AA1 30A Black
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|
BLS7222
$17.49
Quantity in Basket:
none
|
Circuit Breaker AA1 30A White
Circuit Breaker AA1 30A White
| Weight Lb (Kg) | 0.17 (0.08) |
|---|
| Mounting Screw | # 8-32 - Recommended torque 6-8 in-lb |
|---|
| Rated Switch Cycles | 10,000 @ rated amperage and voltage |
|---|
| Trip Time Delay | See |
|---|
| Circuit Breaker Type | Magnetic Hydraulic - trip free |
|---|
| Maximum Voltage Rating | 277 Volts AC, 65 Volts DC |
|---|
| Operating Temperature Range | -40 degrees C to +85 degrees C |
|---|
| Interrupt Rating | See Interrupt Rating table |
|---|
| Terminal Screw | # 10-32 SS with external tooth lock washer - Recommended torque 14-15 in-lb |
|---|
Meets American Boat and Yacht Council (ABYC) standardsUL 1077 recognized, TUV certified, CE Marked for Europe, and CSA certified for CanadaThe industry standard circuit breaker for Blue Sea Systems' electrical panelsCombines swtiching and circuit protection into a single device"Trip Free" design cannot be held "ON" during fault current condition
Trip Delay Curve
|